Automatic internal cardioverter defibrillator associated endocarditis

Authors

  • Amanda Alves Interna do Internato Complementar de Medicina Interna, Serviço de Medicina do Hospital Garcia de Orta, Almada
  • Cristina Martins Interna do Internato Complementar de Cardiologia, Serviço de Medicina do Hospital Garcia de Orta, Almada
  • Carlos Martins Assistente Hospitalar Graduado de Medicina Interna, Serviço de Medicina do Hospital Garcia de Orta, Almada
  • Álvaro Carvalho Director Clínico e Responsável do Serviço de Medicina Interna, Serviço de Medicina do Hospital Garcia de Orta, Almada

Keywords:

endocarditis, automatic internal cardioverter defibrillator (AICD), antibiotic prophylaxis

Abstract

The authors present a clinical case of bacterial
endocarditis, in a 70 years old man, with an automatic
internal cardioverter defibrillator. The tricuspid and
mitral valves were simultaneously involved and septic
pulmonary emboli with respiratory compromise
occurred. Enterococcus faecalis was the bacterial
agent identified. Pulmonary tuberculosis was also
diagnosed in this patient. A revision of the literature concerning endocarditis
in patients with intra-cardiac prosthetic devices is
made. The risk factors associated, the role of
prophylactic antibiotics and the therapeutic options
are discussed.

Downloads

Download data is not yet available.

References

Vlay SC. Stony Brook, N.Y. Prevention of bacterial endocarditis in patients with permanent pacemakers and automatic internal

cardioverter defribrillators. American Heart Journal 1990; 120:1490-1492.

Da Costa A, Kirkorian G, Cucherat M et al. Antibiotic Prophylaxis for Permanent Pacemaker Implantation. A Meta-Analysis.

Circulation 1998; 97: 1796-1801.

Da Costa A, Kirkorian G, Chevalier P et al. Infections Secondary to implantation of cardiac pacemakers. Arch Mal Coeur Vaiss 1998

; 91 (6): 753-757.

Voet JG, Vandekerckhove YR, Muyldermans LL, Missault LH, Matthys LJ. Pacemaker lead infection :report of three cases and

review of the literature. Heart 1999; 81(1): 88-91.

Balbi M, Bertero G, Bellotti Rollandeli ML, Caponnetto S. Rightsided valvular endocarditis supported by an unexpected intracardiac

foreign body. Chest 1990;97:1486-1488.

Werner GS, Gonska BD, Herse B, Kreuser H. Bacterial endocarditis of the transverse lead of an implantable cardioverter/defibrillator.

Z Kardiol 1995; 84: 51-54.

Cacoub P, Leprince P, Nataf P et al. Pacemaker Infective Endocarditis. Am J Cardiol 1998; 82: 480-484.

Arber N, Pras E, Copperman Y et al. Pacemaker Endocarditis. Report of 44 cases and review of the literature. Medicine 1994; 73:

-305.

Selton-Suty C, Hoen B, Grentzinger A et al. Clinical and bacteriological characteristics of infective endocarditis in the elderly.

Heart 1997; 77: 260-263.

Victor F, De Place C, Camus C, Le Breton H, Leclercq C, Pavin D, Mabo P, Daubert C. Pacemaker lead infection: echocardiographic

features, management and outcome. Heart 1999 ; 81 (1): 82-87.

Gevigney G, Pop C, Delehaye JP. The risk of infective endocarditis after cardiac surgical and interventional procedures. European

Heart Journal 1995; 16 (supplement B): 7-14

Additional Files

Published

2001-03-30

How to Cite

1.
Alves A, Martins C, Martins C, Carvalho Álvaro. Automatic internal cardioverter defibrillator associated endocarditis. RPMI [Internet]. 2001 Mar. 30 [cited 2024 Nov. 17];8(1):10-4. Available from: https://revista.spmi.pt/index.php/rpmi/article/view/1889

Issue

Section

Case Reports