Can carotid ultrasound predict the presence of complex atheromatosis of the aortic arch?

Authors

  • Tiago Tribolet de Abreu Laboratório de Ultrasonografia Cardíaca e Neurovascular, Hospital do Espírito Santo-Évora
  • Sónia Mateus Laboratório de Ultrasonografia Cardíaca e Neurovascular, Hospital do Espírito Santo-Évora
  • Cecília Carreteiro Laboratório de Ultrasonografia Cardíaca e Neurovascular, Hospital do Espírito Santo-Évora
  • Irene Mendes Laboratório de Ultrasonografia Cardíaca e Neurovascular, Hospital do Espírito Santo-Évora
  • José Correia Laboratório de Ultrasonografia Cardíaca e Neurovascular, Hospital do Espírito Santo-Évora

Keywords:

acute ischemic stroke, transoesophageal echocardiography, carotid ultrasound, complex atheromatosis of the aortic arch, high-risk carotid plaques

Abstract

Background: The diagnosis of complex atheromatosis of the aortic
arch, a potential source of cerebral emboli, is made by transoesophageal echocardiography (TEE). Although a correlation has been
found between carotid and aortic atherosclerosis, it is not known
how reliably the results of the carotid ultrasound evaluation can
predict the presence of atheromatosis of the aortic arch.
Methods: We prospectively studied all patients referred to our
laboratory simultaneously for TEE and carotid ultrasound, with the
diagnosis of acute ischemic CVA. We evaluated the capacity of an
increased carotid intimal-media thickness (IMT) or the presence of
carotid high-risk atherosclerotic plaques to predict the presence
of complex atheromatosis of the aortic arc.
Results: A total of 101 ischemic stroke patients were sent to
our laboratory for TEE and carotid ultrasound. Considering the
presence of complex atheromatosis of the aortic arch as the
dependent variable, increased carotid IMT had a sensitivity of
42% and a specificity of 78% (positive predictive value 41%,
negative predictive value 80%), and carotid high-risk plaques had
a sensitivity of 22% and a specificity of 95% (positive predictive
value 60%, negative predictive value 77%).
Conclusions: In this study, a carotid ultrasound scan with an
abnormal IMT or high-risk plaques had a high specificity for the
presence of complex atheromatosis of the aortic arch, with a
low sensitivity.

Downloads

Download data is not yet available.

References

Amarenco P, Cohen A, Tzourio C et al. Atherosclerotic disease of the aortic arch and the risk of ischemic stroke. N Engl J Med 1994; 331: 1474-9.

Jones EF, Kalman JM, Calafiore P, Tonkin AM, Donnan GA. Proximal aortic atheroma: an independent risk factor for cerebral ischemia. Stroke 1995; 26: 218-224.

Daniel WG, Erbel R, Kasper W et al. Safety of transesophageal echocardiography: a multicenter survey of 10,419 examinations. Circulation 1991; 83: 817-821.

Pearson A, Peterson JW, Orsinelli DA et al. Comparison of thickness and distensibility in the carotid artery and descending thoracic aorta: in vivo ultrasound assessment. Am Heart J 1996; 131: 655-662.

Harloff A, Handke M, Geibel A et al. Do stroke patients with normal carotid arteries require TEE for exclusion of relevant aortic plaques? J Neurol Neurosurg Psychiatry 2005; 76 (12). 1654-1658.

Pignoli P, Tremoli E, Poli A, Oreste P, Paoletti R. Intimal plus medial thickness of the arterial wall: a direct measurement with ultrasound imaging. Circulation 1986; 74 (6): 1399-1406.

Gray-Weale AC, Graham JC, Burnett JR et al. Carotid artery atheroma: comparison of preoperative B-mode ultrasound appearance with carotid endarterectomy specimen pathology. J Cardiovasc Surg 1988;29:676–681.

Geroulakos G, Ramaswami G, Nicolaides A et al. Characterization of symptomatic and asymptomatic carotid plaques using high-resolution real-time ultrasonography. Br J Sur. 1993;80:1274–1277.

Seward JB, Khandheria BK, Oh JK, Abel MD, Hughes RW, Edwards MD, Nichols BA, Freeman WK, Tajik AJ. Transesophageal echocardiography:

technique, anatomic correlations, implementation and clinical applications. Mayo Clin Proc 1988; 63: 649-680.

Katz ES, Tunick PA, Rusinek H, Ribakove G, Spencer FC, Kronzon I. Protruding aortic atheromas predict stroke in elderly patients indergoing

cardiopulmonary bypass: experience with intraoperative transesophageal echocardiography. J Am Coll Cardiol 1992; 20: 70-77.

Karalis DG, Chandrasekaran K, Victor MF, Ross JJ Jr, Mintz GS. Recognition and embolic potential of intraaortic atherosclerotic debris. J Am Coll Cardiol 1985; 17: 73-78.

Hack W, Kaste M, Bogousslavski J, Brainin M, Chamorro A, Lees K, Leys D, Kwiecinski H, Toni P, Langhorne P, Diener C, Hennerici M, Ferro J, Sivenius J, Gunnar N, Bath P, Olsen TS, Gugging M; European Stroke Initiative Executive Comittee and the EUSI Writing Comittee. European Stroke Initiative Recommendations for Stroke Management: update 2003. Cerebrovasc Dis 2003; 16: 311-337.

Adams HP Jr, Adams RJ, Brott T, del Zoppo GJ, Furlan A, Goldstein LB, Grubb RL, Higashida R, Kidwell C, Kwiatkowski TG, Marler JR, Hademenos GJ; Stroke Council of the American Stroke Association. Guidelines for the early management of patients with ischemic stroke: a scientific statement from the Stroke Council of the American Stroke Association. Stroke 2003; 34: 1056-1083.

Tribolet de Abreu T, Mateus S, Correia J. Therapy implications of transthoracic echocardiography in acute ischemic stroke patients. Stroke 2005; 36: 1565-1566.

McNamara RL, Lima JAC, Whelton PK, Powe NR. Echocardiographic identification of cardiovascular sources of emboli to guide clinical management of stroke: a cost-effectiveness analysis. Ann Intern Med 1997; 127: 775-787.

Blum A, Reisner S, Farbstein Y. Transesophageal echocardiography vs. transthoracic echocardiography in assessing cardio-vascular sources of emboli in patients with acute ischemic stroke. Med Sci Monit 2004; 10: CR521-523.

Agmom Y, Khandheria BJ, Gentile F, Seward JB. Clinical and echocardiographic characteristics of patients with left atrial thrombus and sinus rhythm. Circulation 2002; 105: 27-31.

Cabral S, Oliveira F, Pereira S, Caiado L, Oliveira A, Torres S, Gomes L. Transesophageal echocardiography in the assessment of patients presenting with ischemic cerebral events without previous evidence of a cardiac source of emboli. Rev Port Cardiol 2001; 20: 247-258.

Leung DY, Black IW, Cranney GB, Walsh WF, Grimm RA, Stewart WJ, Thomas JD. Selection of patients for transesophageal echocardiography after stroke and systemic embolic events: role of transthoracic echocardiography. Stroke 1995; 26: 1820-1824.

Nighoghossian N, Perinetti M, Barthelet M, Adeleine P, Trouillas P. Transesophageal echocardiography in patients less than 60 years of age without obvious cardiac souce of embolism. Neurol Res 1995; 17: 368-372.

Warner MF, Momah KI. Routine transesophageal echocardiography for cerebral ischemia. Is it really necessary? Archives of Internal Medicine 1996; 156: 1719-1723.

Kizer JR, Devereux RB. Patent foramen ovale in young adults with unexplained stroke. N Engl J Med 2005; 353: 2361-2372.

Albin MS, Wills J, Schwend RM, Mazzucco S, Anzola GP, Kizer JR, Devereux RB. Patent foramen ovale and unexplained stroke. N Engl J Med 2006; 354: 1753-1755. Correspondence

Additional Files

Published

2011-12-30

How to Cite

1.
Tribolet de Abreu T, Mateus S, Carreteiro C, Mendes I, Correia J. Can carotid ultrasound predict the presence of complex atheromatosis of the aortic arch?. RPMI [Internet]. 2011 Dec. 30 [cited 2024 Sep. 16];18(4):208-11. Available from: https://revista.spmi.pt/index.php/rpmi/article/view/1340

Issue

Section

Original Articles

Most read articles by the same author(s)

<< < 1 2